B0063191 / 1.3
4.3

Mounting of sensors

The sensors must be installed opposite each other in alignment. If circumstances require it, the
mechanical mounting angles can be rotated or swapped.
To ensure an accurate measurement, ensure that the laser axes of the two sensors are identical
(on each other). For this purpose Roland Electronic provides the bracket SHLAS40H, which allows
easy alignment (not shown). The sensors provided within the sensor system LAAS40 have already
been aligned using the bracket SHLAS40H.
For an initial installation, they can be mounted directly. If the sensors are adapted or exchanged,
they must be aligned before mounting.
Fig. 8: Dimensions of the sensors
To prevent contamination of the sensors it is necessary to provide a continuous air blow-off.
See chapter 4.3.8 "Air blow-off for laser sensors".
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Control System R1000 series L20
with integrated fieldbus interface
Attention
In general baffles must be mounted in order to prevent damage to
the sensors at incoming coil / sheet.
Manual
The provided bracket SHLAS40H is not shown above.
Mounting
All dimensions in mm.
19