B0063191 / 1.3
4.3.1
Air blow-off for laser sensors
To prevent contamination of the sensors it is necessary to provide a continuous air blow-off.
This is done by connecting an air hose with 8 mm outer diameter.
A permanent air blow-off of approx. 0.5 bar pressure is recommended, alternatively 5 bar
cyclic cleaning.
Possible contamination
Oil, oil mist, water
Rough tinder
Dust, fine tinder
Note
To disconnect the hose use an 8 mm or 9 mm open-ended wrench as shown in Fig. 6, right.
For the supplied purging air there are requirements regarding purity and freedom from oil.
The requirements are:
Operating medium: compressed air according to ISO 8573-1: 2010 [-: 9: -] inert gases (see
table)
Air purity class at the output: compressed air in accordance with ISO 8573-1: 2010 [1: 7: 2] inert
gases (see table)
Oil freedom: remaining oil content 0.01 mg / m
Class
Solid air particles
ISO 8573-
Max. number of particles per m
1:2010
0.1 – 0.5 μm
0
As determined by the device users, more stringent requirements than class 1
1
≤ 20.000
2
≤ 400.000
3
̶
4
̶
5
̶
6
̶
7
̶
8
̶
9
̶
X
̶
We recommend a filter and filter regulator from Festo HE-D Mini series.
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Control System R1000 series L20
with integrated fieldbus interface
Air blow-off
Continuous, approx. 0.5 bar
Continuous, approx. 5 bar
Cyclic, approx. 5 bar
Air loss causes contamination!
A process-safe operation will be therefore no longer guaranteed!
3
0.5 – 1.0 μm
1.0 – 5.0 μm
≤ 400
≤ 10
≤ 6000
≤ 100
≤ 90.000
≤ 1000
̶
≤ 10.000
̶
≤ 100.000
̶
̶
̶
̶
̶
̶
̶
̶
̶
̶
Manual
3
Water
Quantity
PDP
(Pressure dew
point)
3
mg/m
°C
̶
≤ -70
̶
≤ -40
̶
≤ -20
̶
≤ +3
̶
≤ +10
≤ 5
̶
5 - 10
̶
̶
̶
̶
̶
> 10
̶
Mounting
Oil
Quantity
Quantity
3
3
g/m
mg/m
̶
0,01
̶
0,1
̶
1
̶
5
̶
̶
̶
̶
≤ 0,5
̶
0,5 - 5
̶
5 - 10
̶
> 10
> 10