Start-up
For L20-XX-S:
Adjustment parameter 4: Calibration deviation
adjust parameter: 4
show calibration
deviation distance
Fig. 51: Selection of the calibration deviation
The measured deviation of the calibration sheet thickness (in mm / inch) is displayed by pressing
the ENTER key. This requires that the calibration sheet has to be inserted.
adjust parameter: 4
AB1:-0.005 mm
Fig. 52: Display of the calibration deviation
Pressing the ENTER key will close the display of the calibration deviation.
For L20-3-XX-S:
Adjustment parameter 4: System test / Alignment
According to the type of sensor used, the device performs the following check:
A)
When connecting the sensor type LAAS40+, LAAS10+ (in preparation) and LAAS200+
(in preparation) the alignment and function control of all activated sensors in the system settings
is performed.
adjust parameter: 4
system test/
alignment
Fig. 53: Display of system test / alignment
Possible selections:
yes
no
80