B0063191 / 1.3
11

Technical records

11.1

Parameter channel commands

When transferring data back to the R1000, transfer first the system data and then
transfer the program data.
Parameter channel commands (Operation)
Command
Open
parameter
channel
Close
parameter
channel
Empty
service
Reset
parameter
channel
Parameter channel commands (Read program parameter)
Command
Measuring
channel
Nominal
thickness
in µm
Nominal
thickness
in 1/10000
inch
Lower
threshold
in 1/10 %
Up
threshold
in 1/10 %
Reserved
Moving
average
Reserved
For data backup via the parameter channel always backup all the parameters (including
reserve). This guarantees the reliable data backup even with future extensions.
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Control System R1000 series L20
with integrated fieldbus interface
Byte 0
Byte 1
Direction
Management Program
of data
index
PLC  L20
0H110100
00h
PLC  L20
PLC  L20
0H111000
00h
PLC  L20
PLC  L20
0H110000
00h
PLC  L20
PLC  L20
00000000
00h
PLC  L20
Byte 0
Byte 1
Direction
Management
Program
of data
index
PLC  L20
0H110001
0H110001
PLC  L20
PLC  L20
0H110001
0H110001
PLC  L20
PLC  L20
0H110001
0H110001
PLC  L20
PLC  L20
0H110001
0H110001
PLC  L20
PLC  L20
0H110001
0H110001
PLC  L20
Reserved
PLC  L20
0H110001
0H110001
PLC  L20
Reserved
PLC  L20
0H110001
PLC  L20
0H110001
Manual
Byte 2
Byte 3
Byte 4
Byte 5
Parameter
User
User
index
data
data
byte 0
byte 1
byte 2
00h
00h
00h
Response identical to transmit command
00h
00h
00h
Response identical to transmit command
00h
00h
00h
Response identical to transmit command
00h
00h
00h
Response identical to transmit command
Byte 2
Byte 3
Byte 4
Byte 5
Parameter
User
User
index
data
data
byte 0
byte 1
01h
00h
00h
01h
00h
00h
02h
00h
00h
02h
00h
00h
03h
00h
00h
03h
00h
00h
04h
00h
00h
04h
00h
00h
05h
00h
00h
05h
00h
00h
06h to
0Fh
10h
00h
00h
10h
00h
00h
11h
12h
00h
00h
12h
00h
00h
Technical records
Byte 6
Byte 7
User
User
Check-
data
data
Range of values
sum
byte 3
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
Byte 6
Byte 7
User
User
Check
data
data
Range of values
sum
byte 2
byte 3
00h
00h
XXh
00h
LByte
XXh
Measuring channel 1
00h
00h
XXh
00h
LByte
XXh
(Depending on sensor)
00h
00h
XXh
00h
LByte
XXh
(Depending on sensor)
00h
00h
XXh
00h
LByte
XXh
00h
00h
XXh
00h
LByte
XXh
Reserved
00h
00h
XXh
0-5
0 = 250 ms
00h
LByte
XXh
1 = 100 ms
2 = 50 ms
Reserved
00h
00h
XXh
00h
00h
XXh
Binary 0001 =
0-99000
0-39300
1-1000
1000-1800
3 = 25 ms
4 = 15 ms
5 = 8 ms
no function
no function
111