Roland R1000 Series Manual page 37

Double sheet control system with integrated fieldbus interface
Hide thumbs Also See for R1000 Series:
Table of Contents

Advertisement

B0063191 / 1.3
6.3.1
Process channel – functions and signals
Byte 8 to 11:
Inputs (PLC  L20)
Byte.Bit
Meaning
System test
BIN8.0
Measurement start
BIN8.1
Calibration
BIN8.2
BIN8.3
Dummy function
---
BIN8.4
Clear 2-Blech / clear 0-1-2-outputs
BIN8.5
Program switch
BIN8.6
Reset function fault
BIN8.7
BIN9.0
BIN9.1
BIN9.2
BIN9.3
Measuring program number for program
switching
BIN9.4
BIN9.5
BIN9.6
BIN9.7
---
BIN10.0
---
BIN10.1
---
BIN10.2
---
BIN10.3
---
BIN10.4
---
BIN10.5
---
BIN10.6
---
BIN10.7
BIN11.0
---
---
BIN11.1
---
BIN11.2
Dummy Function
BIN11.3
Dummy Function
BIN11.4
---
BIN11.5
---
BIN11.6
Range (only L20-3-XX-S)
BIN11.7
Explanation of summary output 0-sheet, 1-sheet and 2-sheet:
If the unit is operated in the sequencer mode (program with more sensors e.g. 1+2+3), the measurement result is formed as
summary output. Only the active sensors are included.
2-sheet
is issued if at least one sensor detects 2-sheet.
1-sheet
is issued if all sensors detect 1-sheet.
0-sheet
is issued if no 2-sheet is detected but at least one sensor detects 0-sheet.
If the results of individual sensors are required, then interrogate bytes 12-23.
1)
If a fault occurs at the equipment an operator intervention is required e.g. memory error, low or missing voltage.
2),3), 4)
Footnotes see next chart "Byte 12 to 14"
5)
At R1000 systems with multiple measuring points, these outputs are issued as "summary output" for all measuring points;
as this equipment has only one measuring point available, the result of the measuring point 1 will be outputted.
6)
This function is implemented only in L20-3-XX-S (L20-XX-S in preparation).
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Control System R1000 series L20
with integrated fieldbus interface
6)
3)
3)
3)
Manual
Ausgänge (L20  PLC)
Byte.Bit
Meaning
Function result
BOUT8.0
Always „1"(High)
BOUT8.1
Function fault (1 = Fault)
BOUT8.2
BOUT8.3
Ready (0 = Fault)
2)
Warning
BOUT8.4
2)
0-sheet
(summary output
BOUT8.5
2)
1- sheet
(summary output
BOUT8.6
2)
2- sheet
(summary output
BOUT8.7
BOUT9.0
BOUT9.1
BOUT9.2
BOUT9.3
Actual measuring program
BOUT9.4
BOUT9.5
BOUT9.6
BOUT9.7
BOUT10.0
BOUT10.1
BOUT10.2
BOUT10.3
High Byte Messwert
BOUT10.4
BOUT10.5
BOUT10.6
BOUT10.7
BOUT11.0
BOUT11.1
BOUT11.2
BOUT11.3
Low Byte measuring value
Measuring channel 1
BOUT11.4
BOUT11.5
BOUT11.6
BOUT11.7
Communication with the PLC
1)
5)
)
5)
)
5)
)
4)
Measuring channel 1
4)
37