Fault messages, causes and remedies
9.10

Sensors / Sensor cables faults

No.
Cause
180
Measuring channel 1: Sensor incompatible at connection A
181
Measuring channel 1: Sensor incompatible at connection B
182
Measuring channel 2: Sensor incompatible at connection A
183
Measuring channel 2: Sensor incompatible at connection B
184
Measuring channel 3: Sensor incompatible at connection A
185
Measuring channel 3: Sensor incompatible at connection B
186
Measuring channel 1:
187
Measuring channel 2:
188
Measuring channel 3:
190
Measuring channel 1: Sensor not responding at connection A
191
Measuring channel 1: Sensor not responding at connection B
192
Measuring channel 2: Sensor not responding at connection A
193
Measuring channel 2: Sensor not responding at connection B
194
Measuring channel 3: Sensor not responding at connection A
195
Measuring channel 3: Sensor not responding at connection A
196
Measuring channel 1:
197
Measuring channel 2:
198
Measuring channel 3:
201
Measuring channel 1: Sensor at connection A could not
determine any gap, while the same sensor determined a gap
at connection B
202
Measuring channel 1: Sensor at connection B could not
determine any gap, while the same sensor determined a gap
at connection A
203
Measuring channel 1: The beam alignment is no longer
optimal
204
Measuring channel 2: Sensor at connection A could not
determine any gap, while the same sensor determined a gap
at connection B
205
Measuring channel 2: Sensor at connection B could not
determine any gap, while the same sensor determined a gap
at connection A
206
Measuring channel 2: The beam alignment is no longer
optimal
207
Measuring channel 3: Sensor at connection A could not
determine any gap, while the same sensor determined a gap
at connection B
208
Measuring channel 3: Sensor at connection B could not
determine any gap, while the same sensor determined a gap
at connection A
209
Measuring channel 3: The beam alignment is no longer
optimal
211
Measuring channel 1:
212
Measuring channel 2:
213
Measuring channel 3:
106
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Control System R1000 series L20
with integrated fieldbus interface
Sensor incompatible
Sensor not responding
Communication problems
Manual
Remedy
Contact Roland Electronic or replace sensor
Check / replace sensor cable; replace sensor
Check if
• Sensor A is contaminated
• Sheet to be measured is out of measuring
window
Further details see system parameter 21
Check if
• Sensor B is contaminated
• Sheet to be measured is out of measuring
window
Further details see system parameter 21
Perform system alignment 4 „System
test"/alignment and realign the sensors,
eventually clean the optics
see Nr. 201
see Nr. 202
see Nr. 203
see Nr. 201
see Nr. 202
see Nr. 203
In case of repeated appearance please contact
Roland Electronic.