EDS file for CanOpen
The EDS file contains the specific configuration data of the slaves. The data must be known to the
master.
The manufacturers of the master supply the tools for the integration of the EDS file into the
network. Roland Electronic does not supply such tools, because they have to be compatible with
the interface design of the master.
The EDS file is supplied on a CD or can be downloaded from the Roland homepage.
By pressing the key "
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Control System R1000 series L20
with integrated fieldbus interface
Note
3 PDOs with 8 Bytes each are set.
" status indicators are shown on the display.
Nr.
LED
State
LED 1 STATUS
Off
Red
LED 2 RUN
Off
Green
Green, single flash
Green, blinking
Red, blinking
LED 3 ERROR
Off
Red
Red, single flash
Red, double flash
Red, triple flash
LED 4 POWER
Off
Green
Manual
Status Indicators
Description
Normal operation
Unrecoverable fault detected
Module not powered
Module is in the OPERATIONAL state
Module is in the STOPPED state
Module is in the PRE-OPERATIONAL state
Bus initialisation fault
No error
Bus off
Warning limit reached
Error Control Event
Sync Error
Module not powered
Module powered
Communication with the PLC
61