Communication with the PLC
6.6.2
EDS file for DeviceNet
The EDS file contains the specific configuration data of the slaves. The data must be known to the
DeviceNet master.
The manufacturers of the DeviceNet master supply the tools for the integration of the EDS file into
the DeviceNet network. Suitable are for example the Allen-Bradley DeviceNet manager. Roland
Electronic does not supply such tools, because they have to be compatible with the interface
design of the master.
The EDS file is supplied on a CD or can be downloaded from the Roland homepage.
By pressing the key "
60
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Control System R1000 series L20
with integrated fieldbus interface
Note
24 Bytes I/O must be set.
" status indicators are shown on the display.
Nr.
LED
State
LED 1 ---
---
LED 2 Network
Off
Status
Green
(NS)
Green, flashing
Red
Red, flashing
Alternating
Red / Green
LED 3 Module
Off
Status
Green
(MS)
Green, flashing
Red
Red, flashing
Alternating
Red / Green
LED 4 ---
---
Manual
Status Indicators
Description
Not used
Not powered, not on line
On line, one or more connection established
On line, no connection established
Critical link failure
One or more connections timed out
Device self-test in progress
No power
Normal operation
Auto Baud in progress
Major fault
Minor fault
Device self-test in progress
Not used
B0063191 / 1.3