Command
RCNT loop
RMST loop
RMST l ch
To maintain the clock controller, follow
controller using LD 60" (page
Procedure 49
Maintaining the clock controller using LD 60
Step
1
2
3
Table 36
Clock controller maintenance (LD 60)
Command
DIS CC l s
ENL CC l s
SSCK l s
TRCK aaa l s

Maintain downloadable D-channels

D-channel commands for the DDCH/MSDL are supported for the E1/T1
card. See
Procedure 50
Maintaining the DDCH using LD 96
Media Gateway 1000E PRI Gateway Installation and Commissioning
Description
Reset alarm counter of DTI/PRI loop.
Perform self-test on loop.
Perform self-test on specified channel (2.0 Mb/s DTI/PRI only.)
Action
Log on to the CS 1000E.
To access LD 60, enter:
LD 60
Enter the commands as shown in
maintenance (LD 60)" (page
Description
Disable system clock controller on specified superloop and shelf.
Enable system clock controller on specified superloop and shelf.
Get status of system clock on specified superloop and shelf
Configure clock controller on IPMG specified by the superloop and shelf
tracking to primary, secondary or free run, where aaa is:
PCK = track primary clock
SCLK = track secondary clock
FRUN = free run mode
Procedure 50 "Maintaining the DDCH using LD 96" (page
Nortel Communication Server 1000
NN43041-311 04.01 4 June 2010
Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
Maintain downloadable D-channels 127
--End--