92 Configure an E1/T1 card
Table 22
D-channel configuration example
Prompt
Response
REQ
CHG
TYPE
CEQU
...
PRI2
200
4 0 3
MG_CARD
...
PRI2
201
MG_CARD
4 0 4
...
TYPE
ADAN
ADAN
NEW DCH 70
CTYP
MSDL
MG_CARD
4 0 4
0
PORT
200
DCHL
...
...
ADAN
NEW DCH 71
CTYP
MSDL
4 0 4
MG_CARD
PORT
1
DCHL
201
...
...
Media Gateway 1000E PRI Gateway Installation and Commissioning
Description
New data.
Make changes to common equipment parameters.
Digital loop (2.0 Mb) number 200.
The first PRI2 loop (simulating physical card 3 on the PRI
Gateway) – superloop 4, shelf 0 (PRI Gateway), card 3.
Digital loop (2.0 Mb) number 201.
The second PRI2 loop (simulating physical card 4 on the PRI
Gateway) – superloop 4, shelf 0 (PRI Gateway), card 4.
Action device and number.
Add a D-channel interface on logical port 70.
D-channel configuration on MSDL card.
MSDL= NTBK51AA/NTBK51CA downloadable D-channel
daughterboard.
Simulated physical location of DDCH NTBK51AA/NTBK51CA
daughterboard in the PRI Gateway.
The format is: superloop, shelf number, card number (even
card number - 4).
Port 0 of the NTBK51AA/NTBK51CA daughterboard handles
the interface.
The E1 loop served by this interface (200).
Add a D-channel on logical port 0 - 254.
D-channel configuration on MSDL card.
MSDL= NTBK51AA/NTBK51CA Downloadable D-channel
daughterboard.
Simulated physical location of DDCH.
NTBK51AA/NTBK51CA daughterboard in the PRI Gateway.
The format is: superloop, shelf number, card number. (even
card number – 4)
Port 1 of the NTBK51AA/NTBK51CA daughterboard handles
the interface.
The E1 loop served by this interface (201).