Nortel 1000E PRI Installation And Commissioning Manual page 131

Hide thumbs Also See for 1000E PRI:
Table of Contents

Advertisement

5
To list the PRI alarm counters, enter:
LD 60
LCNT (L)
The response is:
PRI2 LOOP L
MNT NNDC NNC OOS
BVP- xxx xxx xxx xxx
FAP- xxx xxx xxx xxx
SLP- xxx xxx xxx xxx
CRC- xxx xxx xxx xxx
G2 xxx xxx xxx xxx
MAINT NONEWCALL UNAVAIL SEVERE
TOTAL 24HR BVP - XXXXXXXXX XXXXXXXXX XXXXXXXXX
XXXXXXXXX
TOTAL 24HR CRC - XXXXXXXXX XXXXXXXXX XXXXXXXXX
XXXXXXXXX
TOTAL 24HR FAP - XXXXXXXXX XXXXXXXXX XXXXXXXXX
XXXXXXXXX
TOTAL 24HR SLPREP - XXXXXXXXX
TOTAL 24HR SLPDEL - XXXXXXXXX
TOTAL 24 HOUR G2 AIS - XXXXXXXXX
TOTAL 24 HOUR G2 LFAS - XXXXXXXXX
TOTAL 24 HOUR G2 LMAS - XXXXXXXXX
TOTAL 24 HOUR G2 RAI - XXXXXXXXX
TOTAL 24 HOUR G2 LOS - XXXXXXXXX
TOTAL 24 HOUR G2 RAIE - XXXXXXXXX
6
To check the status of the DCH link and the status of the MSDL
card, enter:
LD 96
STAT MDSL sl s c FULL
7
Check that the PRI cables are connected to the E1/T1 span
connectors.
Nortel Communication Server 1000
Media Gateway 1000E PRI Gateway Installation and Commissioning
NN43041-311 04.01 4 June 2010
Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
PRI startup 131
--End--