90 Configure an E1/T1 card
Table 20
PRI2/Euro D-channel interface configuration (LD 17)
Prompt
Response
REQ
CHG
TYPE
ADAN
ADAN
NEW DCH xx
CTYP
MSDL
MG_CARD
supl sh card
0 - 1
PORT
USR
PRI
IFC
EURO
aaaa
CNTY
...
...
0 - 254
DCHL
SIDE
(USR) NET
...
...
Use
Gateway using LD 17" (page 90)
interface in the PRI Gateway.
Procedure 21
Configuring DPNSS/DASS D-channels in the PRI Gateway using LD 17
Step
1
2
Media Gateway 1000E PRI Gateway Installation and Commissioning
Description
Change existing data.
Action device and number.
Add a D-channel on logical port 0 - 254.
D-channel configuration on MSDL card.
MSDL= NTBK51AA/NTBK51CA downloadable D-channel
daughterboard.
TMDI is not supported for the PRI Gateway.
The physical card for the digital loop association to the PRI
Gateway.
The format is: superloop, shelf number, card number.
ATTENTION
Even card numbers are applicable (2, 4, 6, 8).
Port number of the NTBK51AA/NTBK51CA for the
D-channel.
This D-channel is used for Primary Rate only.
Interface type for the D-channel.
Country
Loop number for the D-channel. (See PRI2 loop number.)
The system is network/user side.
Procedure 21 "Configuring DPNSS/DASS D-channels in the PRI
Action
Log on to the CS 1000E.
To access LD 17, enter:
LD 17
Nortel Communication Server 1000
NN43041-311 04.01 4 June 2010
Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
--End--
to configure the DPNSS D-channel