DPNSS/DASS configuration - DDSL data blocks
Procedure 22 "Configuring DPNSS/DASS D-channel interface using LD
74" (page 93)
blocks used for DPNSS protocols.
Procedure 22
Configuring DPNSS/DASS D-channel interface using LD 74
Step
1
2
3
Table 23
DPNSS/DASS D-channel interface configuration (LD 74)
Prompt
Response
REQ
NEW
TYPE
DDSL
0
S2
DDSL
0 - 15
SIGL
DA
DDCS
0 - 254
PRIV
YES/NO
SIDE
AET/BNT
...
...
Configure CE-MUX clock controllers
You must configure the CE-MUX clock controllers as well as error
detection thresholds in PRI Gateway.
These prompts are enabled when the IPMG package (package number
403) is enabled, regardless of the state of the softswitch package.
Media Gateway 1000E PRI Gateway Installation and Commissioning
describes the configuration required for the DDSL data
Action
Log on to the CS 1000E.
To access LD 74, enter:
LD 74
Enter the responses shown in
D-channel interface configuration (LD 74)" (page
Description
New data.
Digital Signaling Link.
DCHI switch setting (the normal addressing mode for
MGP).
The D-channel logical port number, entered in LD 17.
DPNSS1/DASS2 digital signaling.
Loop number used for the PRI link (reference to DDCS in
LD 17).
YES = Private DPNSS1 link.
NO = DASS2 link.
The AET/BNT end of DPNSS1 link.
Nortel Communication Server 1000
NN43041-311 04.01 4 June 2010
Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
Configure E1/T1 ports on a Call Server 93
Table 23 "DPNSS/DASS
--End--
93).