Response
MG_CARD
supl sh card
0 - 1
PORT
USR
PRI
IFC
NI2
DCHL
0 - 254
SIDE
(USR) NET
...
...
Use the steps in
support PRI2/EURO D-channels using LD 17" (page 89)
PRI2/Euro D-channel interface for the PRI Gateway.
Procedure 20
Configuring a D-channel interface to support PRI2/EURO D-channels using
LD 17
Step
1
2
3
Media Gateway 1000E PRI Gateway Installation and Commissioning
Description
The physical card for the digital loop association to the PRI
Gateway.
The format is: superloop, shelf number, card number.
ATTENTION
Even card numbers are applicable (that is, 2, 4, 6, 8).
Port number of the NTBK51AA/NTBK51CA for the
D-channel.
ATTENTION
For the PRI Gateway, the following software package for
the functionality that allows the use of port 0 or port 1 is
provided in CS 1000 Extended Media Gateway PRI (MGP)
package 418
This D-channel is used for Primary Rate only.
Interface type for the D-channel.
Loop number for the D-channel. (See DLOP loop number.)
The system is network/user side.
Procedure 20 "Configuring a D-channel interface to
Action
Log on to the CS 1000E.
To access LD 17, enter:
LD 17
Enter the responses shown in
interface configuration (LD 17)" (page
Nortel Communication Server 1000
NN43041-311 04.01 4 June 2010
Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
Configure E1/T1 ports on a Call Server 89
WARNING
DO NOT use odd loop numbers. Odd loop
numbers may cause issues with existing
equipment.
--End--