Media Gateway 1000E PRI Gateway Installation and Commissioning
Description
The IPMG_TYPE can not
be modified when the link
to the IPMG is established.
The maximum number of
MGTDS loops that can be
configured for a MG 1000E
is 2.
The maximum number of
MGCNF loops that can be
configured for an SSC MG
1000E is 4
The maximum number of
MGCNF loops that can be
configured for a MGC MG
1000E is 2
There are no MGTDS
loops configured in this
IPMG.
Cannot set the IPMG flag
on a non-IPMG loop.
STARTUP: "EXP_CAB"
registration denied.
Unconfigured IP address
nnn.nnn.nnn.nnn.
Nortel Communication Server 1000
NN43041-311 04.01 4 June 2010
Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
Organization of CLI commands 157
Corrective action
Either disconnect
the IPMG from the
network or power off
the IPMG so the link
gets disabled.
Do not configure more
than 2 MGTDS loops
for MG 1000E.
Do not configure more
than 4 MGCNF loops
for an SSC MG 1000E
Do not configure more
than 2 MGCNF loops
for a MGC MG 1000E
Check the configuration
and try again.
Output
(TTY, LOG,
SNMP, LED)
TTY, LOG
TTY, LOG
TTY, LOG
TTY, LOG
TTY, LOG
TTY, LOG
TTY, LOG,
SNMP