72 Configure the Media Gateway Controller and DSP daughterboards in a PRI Gateway
Enter the following information:
The ELAN configuration of the IPMG:
The TLAN configuration of the IPMG (through Element Manager):
Information for the Call Server controlling the PRI Gateway:
Hostname for the PRI Gateway:
You do not need to enter other configuration information on the MGC.
All other information necessary to the operation of the PRI Gateway is
configured through Element Manager and is automatically downloaded
to the MGC from the Call Server.
After configuration is complete and the MGC has rebooted, the MGC
attempts to register to the Call Server. The Call Server then attempts to
match the IP address configured in LD 97 for this PRI Gateway against the
IP address included in the registration request. If either of these checks
fail, appropriate error messages are displayed. For more information, see
"Media Gateway Controller system alarms, events, and messages" (page
155).
MGC configuration information is entered two ways:
If the MGC detects that no IP configuration exists, the setup menu
appears.
Through the mgcsetup shell command.
ATTENTION
Any changes to the configuration of the MGC ELAN must be reflected in similar
changes on the Call Server.
Here is an example of the configuration of an MGC without any installed
DSP daughterboards:
Media Gateway 1000E PRI Gateway Installation and Commissioning
IP address
subnet mask
gateway address
IP address
subnet mask
default gateway address
hostname of the Call Server on the ELAN subnet [optional through
Element Manager]
IP address of the Primary Call Server
hostname of the IPMG [optional through Element Manager]
Nortel Communication Server 1000
NN43041-311 04.01 4 June 2010
Copyright © 2007-2010 Nortel Networks. All Rights Reserved.