Rectifier
1. Inspect for continuity of the diodes using an ohmmeter.
If not as specified, replace the rectifier.
•
Specification
Tester
Negative
Positive
E
P1, P2, P3, P4
B
E
P1, P2, P3, P4
B
Bearing
1. Inspect for abnormal noise, looseness, and sticking.
Replace the bearing if necessary.
•
Continuity
Yes
No
No
Yes
(w)
Engine Specifications