FUEL PUMP UNIT INSPECTION
Fuel Pump Operation Inspection
Without Using WDS or equivalent
CAUTION:
Shorting the wrong terminal of the check connector may cause malfunctions. Make sure to short only
•
the specified terminal.
1. Ground the check connector terminal F/P using the jumper wire.
2. Remove the fuel filler cap.
3. Turn the ignition switch to the ON position and verify that the fuel pump can be heard operating.
If it cannot be verified, inspect for a voltage of 3.76 5.28 V on the fuel pump wiring harness-
•
side connector terminal B.
If it is within the specification, inspect the following.
If not within the specification, inspect the following.
Fuel pump continuity inspection
•
Wiring harness between fuel pump terminal D and GND
•
Fuel pump relay
•
Wiring harnesses, connectors between main relay, fuel pump relay, and check
•
connector
Wiring harnesses, connectors between fuel pump relay, fuel pump resistor, and
•
fuel pump
(w)
Engine Specifications
Page 132