Santerno DCREG2 Series User Manual page 75

Table of Contents

Advertisement

DCREG2
DCREG4
- "JOG": is active only when at least one of the sources selected for the commands corresponds to
KeyPad and, when depressed, it enables the jog mode with a reference equal to the one obtained by
enabling digital input JogA.
FORWARD
- "
": is active only when at least one of the sources selected for the commands corresponds
REVERSE
to KeyPad, and when depressed, it enables the polarity reversal of the Ref n reference applied to the
ramps.
- "START": is active only when at least one of the sources selected for the commands corresponds to
KeyPad and, when depressed, it enables a self-retained run command, with a reference equal to the one
obtained by enabling the START digital input. For the interaction of this key with the START digital inputs
coming from other sources, refer to the Ref n section in the BLOCK DIAGRAM chapter.
- "STOP": in general, it is active only when at least one of the sources selected for the commands
corresponds to KeyPad and, when depressed, it enables a stop command, just as if digital input START
was disabled. For the interaction of this key with the START digital inputs coming from other sources,
refer to the Ref n section in the BLOCK DIAGRAM chapter. In addition, even though none of the sources
selected for the commands corresponds to KeyPad, this key may have the STOP function by setting par.
C103 (EmergStop) to 0:Included.
NOTE
For a simpler use of the drive, the following command shortcuts are available:
- ALARM RESET: Press the "PROG" and "SAVE" keys simultaneously to close a digital input
configured as 0:Reset for an alarm reset. Of course, the alarm will be cancelled once the cause
responsible for its trip has disappeared.
- QUICK PAGE SHIFT (MONITOR function): Press the "  " and "  " keys simultaneously to access
the page relating to parameter P000 (Key). Press "  " and "  " again to access the Keypad page relating
to parameter M000 (Vref) and to other measure parameters selected through parameter P005 (FirstParm)
and P006 (MeasureSel). Press "  " and "  " for the third time to display the Status page. By pressing both
keys once again, the operator may return to the page where the prior keys had been pressed.
- LOCAL MODE SWITCHING for commands and references : Press the "  " and "SAVE" keys
simultaneously to switch to LOCAL mode for the drive commands (digital inputs) and references.
Switching is enabled only when parameter C100 (LocRemSel) is set at value 0:Enabled with the drive
disabled, i.e. not running. Whenever the drive is turned on, it will directly switch to the operating mode
previously saved on EEPROM. Therefore, the LOCAL mode "status" enabled by pressing the "  " and
"SAVE" keys is not included among the variables that can be saved on EEPROM.
When operating, the drive uses the current parameter set, i.e. the parameters
available at the moment. The parameter that has been updated with the "  "
and "  " keys will be immediately used instead of the previous parameter,
even if it is not saved with the "SAVE" key. The new value will not obviously be
stored when the drive is turned off.