P221: J
P221 JogSelect
***
7.2.79
J
OG
P... Jogx
*****
%
SELECTION: Among the three jog references to be stored, the valid one results from the closing of one or
more digital inputs that have been properly configured.
If two digital inputs are set to 12:JogA and 13:JogB, the preset jog reference is determined by the table
below, where a blank square indicates the digital input opening state (or the input that has not been set)
and the black square indicates the closing state:
Selected jog reference
-
Jog1
Jog2
Jog3
If you want to select only one jog reference out of three, you just need to set one input with values
12:JogA for the first and 13:JogB for the second.
R
S
OG
AMP
ELECTION
P
P221 - JogSelect
0 ... 2
R
0
D
This parameter defines the ramps to be assigned to the jog references.
F
0:Common Ramps. The jog references pass through common ramps P030,
P031, P032, P033. When the jog digital input opens, ramp P034 or P035 takes
place, depending on the polarity programmed.
1:Without Ramps. The jog references are directly taken.
2:Separate Ramps. The jog references pass through separate ramps P036,
P037.
Ramp P037 takes place both when the value set in this parameter decreases
and when the jog digital input opens.
R
1(2)(3)
EFERENCE
P
P222(223)(224) - Jog1(2)(3)
-100. ... 100. %
R
P222: 5.00 %
D
P223: -5.00 %
P224: 0.00 %
F
P222: Jog1 Reference.
P223: Jog2 Reference.
P224: Jog3 Reference.
These references are speed / voltage references whose polarity may be
reversed by applying the Reverse function. If a digital input programmed for the
6:Slave function (see par. C130 ... C135) is closed, or if par. C050 has been
directly programmed for the 3:Iref=Vref, then the above-mentioned jog
references become current references.