M024 OutputPower
Pout
**** kW
7.1.26
M025: M
M025 MotorTorque
Torque
**** %
7.1.27
M026: E
M026 EnP/NrFreq
EFreq ****** k Hz
7.1.28
M027: D
M027 Drivelife
*****h **m
7.1.29
M028: P
M028 PhaseSeq
* * *
P
UTPUT
OW ER
M024 – POut
P
0 ... 5250 kW
R
This parameter indicates, in kW, the power supplied to the load, as a division by
F
1000 of the output voltage product (par. M006) for the output current (par.
M004).
T
OTOR
ORQUE
M025 – Torque
P
-180. ... 180. %
R
F
It displays, as a percentage of the motor nominal torque, the motor torque as a
product per cent of the armature current by the field current. 100% of this
parameter is obtained with the motor armature nominal current (set by par.
C000) and the motor field nominal current (set by par. C010).
P/N
F
N
R
REQUENCY
M026 – EFreq
P
-102.4 ... 102.4 k Hz
R
This parameter displays, in k Hz, the frequency of the enP/Nr used as a speed
F
feedback.
L
RIVE
IFE
M027 – Drivelife
P
0 ... 235926000 s (approx. 7 years and a half), size ..h ..m
R
This parameter indicates the drive overall operation time starting from its first
F
power-on. This value is stored each time the power section is shut off.
S
HASE
EQ
M028 – PhaseSeq
P
RST ... TSR
R
Indicates which is the phase sequence supplying the drive section power with
F
reference to bars L1-L2-L3 respectively.
15P0059B3
USER MANUAL
129/200