M008: Mains Frequency; M009: Mains Voltage; M010: Auxiliary Analog Input 1 To Terminals 11 And 13; M011: Auxiliary Analog Input 2 On Terminal 17 - Santerno DCREG2 Series User Manual

Table of Contents

Advertisement

DCREG2
DCREG4
7.1.9 M008: M
AINS
M008 MainsFreq
MFreq
****
Hz
7.1.10
M009: M
M009 MainsV
Vmains ****
V
7.1.11
M010: A
M010 AnalogIn1
AnIn1 *****
%
7.1.12
M011: A
M011 AnalogIn2
AnIn2 *****
%
F
REQUENCY
P
M008 - Frequency
40.0 ... 70.0 Hz (normally displayed range)
R
This parameter indicates, in Hertz, the power supply mains frequency measured
F
on the input bars.
V
AINS
OLTAGE
P
M009 - Vmains
0 ... 1000 V
R
This parameter indicates, in Volts, the mains voltage applied to the drive power
F
section.
A
UXILIARY
NALOG
P
M010 - AnIn1
-100. ... 100. %
R
This parameter indicates, as a percentage of the max. reference corresponding
F
to 10V, the value of the reference resulting from IN 1 reference application
between terminals 11 and 13. The reference obtained may be configured
through parameter C120.
The value per cent displayed in this parameter takes account of the Gain, Bias,
Polarityblocks (see parameters P128, P127 and P126 respectively) and of the
Reverse function which are applied in the above-mentioned order.
The value per cent displayed in this parameter also displays the reference
issued from a current external signal (milliAmperes), provided that jumper
JP408 on the control board is set on position 2-3: if an analog input is to be used
as a 0(4) ... 20mA signal, the value to be set on the parameters relating to Gain
and Bias operators is shown in the MILLIAMPERE INPUT / OUTPUT SIGNALS
chapter.
A
UXILIARY
NALOG
M011 - AnIn2
P
-100. ... 100. %
R
F
This parameter indicates, as a percentage of the max. reference corresponding
to 10V, the value of the reference resulting from IN 2 reference application
between terminal 17 and 0V. The reference obtained may be configured through
parameter C121.
The value per cent displayed in this parameter takes account of the Gain, Bias
and Polarity blocks (see parameters P131, P130 and P129 respectively) and of
the Reverse function - only if an input is configured as a speed additional
reference - applied in the above-mentioned order.
I
1
T
NPUT
TO
ERMINALS
I
2
T
NPUT
ON
15P0059B3
USER MANUAL
11
13
AND
17
ERMINAL
125/200

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents