15P0059B3
USER MANUAL
STANDARDS
WORKING
TEMPERATURES
MAXIMUM OPERATING
ALTITUDE
RELATIVE HUMIDITY
26/200
From speed feedback failure: alarm A008.
From automatic tuning failure: alarms A011, A014, A015, A018 and A019.
From general external failure: alarm A020, A029 and A030.
From EEPROM failure: alarms A024, A025, A026 and A031.
From serial communication failure: alarm A027.
From bus field connection failure: alarm A028.
DCREG drives comply with "Low-Voltage Directive" and "Electromagnetic
Compatibility Directive". As per the "Machine Directive", the DCREG
converters may be integrated into a machine only if installed in compliance
with the installation conditions detailed in this manual; they shall not be
operated before the machine where they are installed has been declared as
compliant to the "Machine Directive".
Said converters particularly comply with the standards below.
Low-voltage DIRECTIVE (2014/35/UE):
EN61800-5-1:2007: Adjustable speed electrical power drive systems. Part 5-
1:Safety requirements – Electrical, thermal and energy.  pollution degree 2
and degree of protection IP00.
ELECTROMAGNETIC COMPATIBILITY DIRECTIVE (2014/30/UE):
EN61800-3:2004 and EN61800-3/AM1:2012 Adjustable speed electrical power
drive systems. Part 3: EMC requirements and specific test methods  second
environment (industrial network), C3 class, without RFI filters; first environment
(public network), C1 and C2 classes, with optional RFI filters.
For the definition of "first environment" and "second environment" and for the
instructions on how to choose the filters to be used, see chapter EMC
CHARACTERISTICS AND INPUT FILTERS.
From 0 to 40°C ambient temperature. 2% derating for each degree of
temperature increase.
1000m (a.s.l.). 1% derating every 100m of altitude increase.
20 ... 90% (non-condensing).
DCREG2
DCREG4