7.3.32
C105(106)(107)(108): S
1(2)(3)(4)
C... RefSelx
***
WARNING
C105(106)(107)(108) – RefSel1(2)(3)(4)
P
0 ...4
R
C105: 1
D
C106: 0
C107: 0
C108: 0
F
C105: Determines reference source n.1.
C106: Determines reference source n.2.
C107: Determines reference source n.3.
C108: Determines reference source n.4.
0:Disabled. This selection does not enable any reference source.
1:Terminal. This selection enables the terminal board as a reference source.
2:UpDownRef. This selection enables the internal Up / Down reference as a
reference source.
3:Serial Link. This selection enables the serial connection as a reference
source.
4:FieldBus. This selection enables the field bus as a reference source.
The user may select max. four sources, therefore the MainRef may by equal to
the sum of the references coming from all four available sources. If the same
source is enabled by two or multiple selections, this corresponds to selecting
this source only once.
For each MIXED  LOCAL switching performed by simultaneously pressing
the "  " and "SAVE" keys, the values of the four parameters change as follows:
C105  2:UpDownRef
C106  0:Disabled
C107  0:Disabled
C108  0:Disabled
These parameters cannot be changed in LOCAL mode.