15P0059B3
USER MANUAL
7.2.17
P032: R
P032 RampUpNeg
*****
sec
NOTE
7.2.18
P033: F
P033 RampDnNeg
*****
sec
NOTE
7.2.19
P034: S
P034 RampStopPos
*****
sec
NOTE
138/200
R
ISE
AMP OF T HE
P
P032 - RampUpNeg
0.000 ... 300.0 s
R
0.000 s
D
Rise ramp time, expressed in seconds, from 0% to 100% of the negative speed
F
/ voltage reference applied to the Main Ref or the Preset Ref (preset run
reference), possibly limited at the minimum and/or maximum value. See also
figure shown in the RAMPS OVER REFERENCE chapter.
As for the real speed ramp, see relevant note stated in parameter P030.
This parameter programming cannot be changed if a digital input configured for
the 7:Ramps Disabled function is closed.
R
ALL
AMP OF THE
P
P033 - RampDnNeg
R
0.000 ... 300.0 s
D
0.000 s
Fall ramp time, expressed in seconds, from 100% to 0% of the negative speed /
F
voltage reference applied to the Main Ref or the Preset Ref (preset run
reference), possibly limited at the minimum and/or maximum value. See also
figure shown in the RAMPS OVER REFERENCE chapter.
As for the real speed ramp, see relevant note stated in parameter P031.
This parameter programming cannot be changed if a digital input configured for
the 7:Ramps Disabled function is closed.
R
TOP
AMP OF THE
P034 - RampStopPos
P
R
0.000 ... 300.0 s
D
0.000 s
F
Fall ramp time, expressed in seconds, from 100% to 0% of the positive speed /
voltage reference applied to the Main Ref or the Preset Ref (preset run
reference), possibly limited at the minimum and/or maximum value, due to the
disabling of the START digital input. See also the figure shown in the RAMPS
OVER REFERENCE chapter.
In order to exactly respect the time set for the stop ramp, the time set in par.
P031 is to be equal to at least 10% of the time set in P034.
Such parameter sets a positive reference fall ramp to be enabled - through the
disabling of the START input - instead of the main ramp defined in parameter
P031.
As for the real speed ramp, see relevant note stated in parameter P031.
This parameter programming cannot be changed if a digital input configured for
the 7:Ramps Disabled function is closed.
N
R
EGATIVE
EFERENCE
N
R
EGATIVE
EFERENCE
P
R
OSITIVE
EFERENCE
DCREG2