P002: Parameter Copy Command; P003: Programming Level - Santerno DCREG2 Series User Manual

Table of Contents

Advertisement

DCREG2
DCREG4
7.2.3 P002: P
ARAMETER
P002 ParmsCopy
***
WARNING
7.2.4 P003: P
ROGRAMMING
P003 ProgLevel
***
C
C
OPY
OMMAND
P002 – ParmsCopy
P
0 ... 3
R
0
D
Access P/N for the parameter copy.
F
0:Disabled. No parameter copy command is sent.
1:DefaultRestore. Restoration of the user's parameter default values.
2:WorkAreaBackup. Backup of the current parameters.
3:Backup Restore. Restoration of the backup parameters.
See also the PARAMETER COPY chapter.
For this parameter, no values other than 0:Disabled may be stored on
EEPROM.
L
EVEL
P003 – ProgLevel
P
0 ... 1
R
D
0
F
0:Basic.
1:Advanced.
Sets the programming level required, chosen between a fast starting base level
with the basic functions and an advanced level for skilled users who want to
optimise the equipment performance.
If this parameter is programmed at 0:Basic, only the following parameters may be
accessed:
M000 (Vref). Reference applied to the ramps.
...
M031 (FBDgIn). Digital input state from field bus.
P000 (Key)
P003 (ProgLevel)
P010 (nFdbkMax)
P011 (VarmMax)
P030 (RampUpPos)
P031 (RampDnPos)
P032 (RampUpNeg)
P033 (RampDnNeg)
P034 (RampStopPos)
P035 (RampStopNeg)
P038 (InitialRndg)
P039 (FinalRndg)
P060 (OverLimA)
P061 (OverLimB)
P086 (ArmatureCmp)
P087 (VerrOffset)
C000 (Inom)
C010 (IfldNom)
C030 (VmainsNom)
C051 (CurrLoopSel)
C070 (nFdbkSelect)
C072 (EnP/NrPls)
C074 (Tach Volts)
If this parameter is set at 1:Advanced, all other parameters may be accessed.