P170(176)(182)(188)(194): Digital Output 1(2)(3)(4)(5) Configuration - Santerno DCREG2 Series User Manual

Table of Contents

Advertisement

15P0059B3
USER MANUAL
7.2.71 P170(176)(182)(188)(194): D
C
ONFIGURATION
P... MDOxCfg
***
WARNING
156/200
P
P170(176)(182)(188)(194) - MDO1(2)(3)(4)(5)Cfg
0 ... 13
R
P170: 0
D
P176: 1
P182: 2
P188: 5
P194: 4
P170: It indicates the configuration of digital output 1 (MDO 1) to terminals 25
F
and 27.
P176: It indicates the configuration of digital output 2 (MDO 2) to terminals 29
and 31.
P182: It indicates the configuration of digital output 3 (MDO 3) to terminals 33
and 35.
P188: It indicates the configuration of digital output 4 (MDO 4) to terminals 37
and 39.
P194: It indicates the configuration of digital output 5 (MDO 5) to terminals 41
and 43.
0:Drive OK. No alarm is active.
1:SpeedThreshold. The speed / voltage threshold set has been overcome.
2:Iarm Threshold. The armature current threshold set has been overcome.
3:Motor at Speed. The speed / voltage set at the ramp circuit input has been
reached - i.e. the ramp transient has been performed. This function is enabled
as long as the drive is running.
4:CurrLimitation. The drive is in a current limit state, i.e. the armature current is
at the max. value allowed at that moment.
5:Drive Running. The drive is running (it is controlling).
6:Full OverLimit. The drive has been in a current overlimit state throughout the
time set in P062.
7: Fld Weakening. The dynamic regulation of the field current in field
weakening mode is in progress.
8: Ifld Threshold. The field current threshold set has been overcome.
9:Vref Threshold. The reference threshold has been overcome.
10:No warnings. No warning is displayed on the Status page.
11:FieldBus. Relay contact reiterated at output, resulting from the conversion of
a digital signal sent by the field bus at input.
12:OUT Timer A. Same output signal as the signal sent to one of configurable
digital inputs MDIx if one of them is set as 19:IN TimerA. This signal is
reproduced
based
MDO1(2)(3)(4)(5)OffDly and based on logics set for MDO1(2)(3)(4)(5)Logic.
13:OUT Timer B. Same output signal as the signal sent to one of configurable
digital inputs MDIx if one of them is set as 20:IN TimerB. This signal is
reproduced
based
MDO1(2)(3)(4)(5)OffDly and based on logics set for MDO1(2)(3)(4)(5)Logic.
The indication provided by the digital input configured as 3:Motor at Speed does
not consider any additional speed reference.
O
IGITAL
UTPUT
on
timing
set
for
on
timing
set
for
DCREG2
DCREG4
1(2)(3)(4)(5)
MDO1(2)(3)(4)(5)OnDelay
MDO1(2)(3)(4)(5)OnDelay
and
and