DCREG2
DCREG4
Emission limits
The standards in force also define the allowable emission level for different environments.
The diagrams below pertain to the emission limits allowed by EN 61800-3 ed.2.
µV
dB (
)
A1 = EN 61800-3 issue 2 FIRST ENVIROMENT, Category C2, EN55011 gr.1 cl. A,
EN50081-2, EN61800-3/A11.
B = EN 61800-3 issue 2 FIRST ENVIROMENT, Category C1, EN55011 gr.1 cl. B,
EN50081-1,-2, EN61800-3/A11.
140
120
100
µV
dB (
)
80
60
40
20
0
0,1
A2 = EN 61800-3 issue 2 SECOND ENVIRONMENT Category C3, EN55011
gr.2 cl. A, EN61800-3/A11.
"FIRST ENVIRONMENT" Disturbance Limits
90
80
70
60
50
40
30
20
10
0
0,1
1
log f (MHz)
"SECOND ENVIRONMENT" Disturbance Limits
1
log f (MHz)
10
100
10
100
USER MANUAL
Quasi-Peak Category C2
Mean value Category C2
Quasi-Peak Category C1
Mean value Category C1
Quasi-Peak I <= 100 A
Mean value I <= 100 A
Quasi-Peak I > 100 A
Mean value I > 100 A
195/200