Alarms - Siemens Sinumerik 802D sl Programming Manual

Iso turning
Hide thumbs Also See for Sinumerik 802D sl:
Table of Contents

Advertisement

Alarms

If error states are detected in cycles, an alarm is generated and cycle execution is
interrupted.
The cycles continue to output messages in the dialog line of the control. These messages do
not interrupt execution.
Alarms with numbers between 61000 and 62999 are generated in the cycles This number
range is subdivided further according to alarm reactions and cancelation criteria.
Table F-1
Alarm number and alarm description
Alarm no.
Brief description
General alarms
61001
Pitch of thread not correct
61003
No feed programmed in cycle
61004
Configuration of geometry axis
not correct
61101
Reference plane improperly de- -
fined
61102
No spindle direction program-
med
61107
First drilling depth incorrectly de-
fined
61603
Grooving incorrectly defined
61607
Start point incorrect
61610
No in- -feed programmed
ISO alarms
61800
External CNC system missing
© SIEMENS AG 2007 All rights reserved
SINUMERIK 802D sl/840D sl840D/840Di sl/840Di/810D ISO Turning - - 04.07 Edition
Source
CYCLE376T
CYCLE371T, CYCLE374T,
CYCLE383T, CYCLE384T,
CYCLE385T, CYCLE381M,
CYCLE383M, CYCLE384M,
CYCLE387M
CYCLE328
CYCLE375T, CYCLE81,
CYCLE83, CYCLE84, CYCLE87
CYCLE371T, CYCLE374T,
CYCLE383T, CYCLE384T,
CYCLE385T, CYCLE381M,
CYCLE383M, CYCLE384M,
CYCLE387M
CYCLE374T
CYCLE376T
CYCLE374T
CYCLE300, CYCLE328,
CYCLE330, CYCLE371T,
CYCLE374T, CYCLE376T,
CYCLE383T, CYCLE384T,
CYCLE385T, CYCLE381M,
CYCLE383M, CYCLE384M,
CYCLE387M
F
Explanation/remedy
Pitch of thread is not specified
correctly
No feed F word was program-
med in the calling block before
the cycle call, see standard Sie-
mens cycles
The order of the geometry axes
is incorrect, see standard
Siemens cycles
See standard Siemens cycles
Spindle direction M03 or M04
missing, see standard Siemens
cycles
First drilling depth counter to
total drilling depth
Grooving depth value 0
The start point is not outside of
the area to be machined
In- -feed value = 0
Machine data for external lan- -
guage MD18800:
$MN_MM_EX- -TERN_ LAN-
GUAGE or option bit 19800
$ON_EXTERN_LAN- -GUAGE is
not set
F-229

Hide quick links:

Advertisement

Table of Contents
loading