10806
MD number
Default setting: 97
Changes effective after Power On
Data type: DWORD
Meaning:
10808
MD number
Default setting: 0
Changes effective after Power On
Data type: WORD
Meaning:
10810
MD number
Default setting: 1
Changes effective after Power On
Datentype: BYTE
Meaning:
© SIEMENS AG 2007 All rights reserved
SINUMERIK 802D sl/840D sl840D/840Di sl/840Di/810D ISO Turning - - 04.07 Edition
EXTERN_M_NO_DISABLE_INT
ASUP deactivating M code
Minimum input limit: 0
Protection level: 2/7
M code to activate interruption type subprogram call in ISO dialect T/M mode (ASUP).
EXTERN_INTERRUPT_BITS_M96
Interrupt program - - Execution (M96)
Minimum input limit: 0
Protection level: 2/7
Using the data bits described below, the behaviour of the interruption type subprogram
activated by M96 P .. can be specified.
Bit 0: =0, Disable interruption type subprogram; M96/M97 are treated as standard M codes
=1, Enable activation/deactivation of interruption type subprogram using M96/M97
Bit 1: =0, Execution of the part program is continued at the target position of the NC block
subsequent to the NC block where the interruption took place
=1, Execution of the part program is continued at the interruption position
Bit 2: =0, The current NC block is interrupted immediatly and the subprogram is called
if the interrupt signal is detected.
=1, The subprogram is called after completion of the current NC block
Bit 3: =0, When detecting an interrupt signal during execution of a machining cycle, the
machining cycle is interrupted.
=1, Interrupt after machining cycle completion
EXTERN_MEAS_G31_P_SIGNAL
Measuring signal input assignment for G31 P..
Minimum input limit: 0
Protection level: 2/7
Measuring inputs 1 and 2 are assigned to the arguments P .. of G31 P1 to P4 command. It
is a bit coded MD. Only bit 0 and bit 1 are evaluated.
For example:
$MN_EXTERN_MEAS_G31_P_SIGNAL[1], Bit 0=1, the 1st measuring input is activated by
G31 P2.
$MN_EXTERN_MEAS_G31_P_SIGNAL[3] = 2, the 2nd measuring input is activated by
G31 P4.
Bit 0:
=0:
Deactivate measuring input 1 for G31 P1 (- -P4)
=1
Activate measuring input 1 for G31 P1 (- -P4)
Bit 1:
=0
Deactivate measuring input 2 for G31 P1 (- -P4)
=1
Activate measuring input 2 for G31 P1 (- -P4)
Machine and Setting Data
D.1 Machine/Setting Data
Maximum input limit:
Unit: - -
Applies with effect from SW version: 6.2
Maximum input limit: 8
Unit: - -
Applies with effect from SW version: 6.2
Maximum input limit: 3
Unit: - -
Applies with effect from SW version: 6.2
D-205