Switching between feed per minute mode and feed per revolu-
tion mode (G94/G95)
Before specifying a feedrate command (F), a G code that determines whether the
specified feedrate command is interpreted as feed per minute value or feed per
revolution value should be specified. These G codes (G94, G95) are modal and
once they are specified they remain valid until the other G code is specified. When
the feed mode designation G code is specified, the presently valid F code is cance-
led. Therefore, an F code must be specified newly after switching the feed mode
by designating G94 or G95 command. The initial status that is established when
the power is turned on is set by
Table 1-4
MD EXTERN_GCODE_RESET_VALUES[4]=1
MD EXTERN_GCODE_RESET_VALUES[4]=2
Feed per minute mode (G94)
By specifying "G94;", the F codes specified thereafter are all executed in the
feed per minute mode.
Feed per revolution mode (G95)
By specifying "G95;", the F codes specified thereafter are all executed in the
feed per revolution mode.
© SIEMENS AG 2007 All rights reserved
SINUMERIK 802D sl/840D sl840D/840Di sl/840Di/810D ISO Turning - - 04.07 Edition
MD 20154, EXTERN_GCODE_RESET_VALUES[4]
MD EXTERN_GCODE_RESET_VALUES[4] and initial
status
MD 20154
Table 1-5
Meaning of G94 command
G94
mm input
inch input
Table 1-6
Meaning of G95 command
G95
mm input
inch input
Programming Basics
1.2 Basics of feed function
Initial G code
G94
G95
Meaning
mm/rev
inch/rev
Meaning
mm/rev
inch/rev
.
1-21