Siemens Sinumerik 802D sl Programming Manual page 204

Iso turning
Hide thumbs Also See for Sinumerik 802D sl:
Table of Contents

Advertisement

Machine and Setting Data
D.1 Machine/Setting Data
10760
MD number
Default setting: 2
Changes effective after Power On
Data type: BYTE
Meaning:
10800
MD number
Default setting: - -1
Changes effective after Power On
Data type: DWORD
Meaning:
This MD cannot SINUMERIK 802D sl.
10802
MD number
Default setting: - -1
Changes effective after Power On
Data type: DWORD
Meaning:
This MD cannot SINUMERIK 802D sl.
10804
MD number
Default setting: 96
Changes effective after Power On
Data type: DWORD
Meaning:
D-204
G53_TOOLCORR
Mode of action when G53, G153 and SUPA is specified
Minimum input limit: 2
Protection level: 2/7
The MD is effective in both Siemens mode and in external language mode.
This machine data defines whether tool length compensation and tool radius compensation
are suppressed with language commands G53, G153 and SUPA.
0 = G53/G153/SUPA is non- -modal suppression of zero offsets, tool length compensation
and tool radius compensation remain active.
1= G53/G153/SUPA is non- -modal suppression of zero offsets, and active tool length and
tool radius compensation.
EXTERN_CHAN_SYNC_M_NO_MIN
First M code for channel synchronization
Minimum input limit: 100
Protection level: 2/7
Lowest number M code out of an M code number area which is reserved for channel syn-
chronization.
EXTERN_CHAN_SYNC_M_NO_MAX
Last M code for channel synchronization
Minimum input limit: 100
Protection level: 2/7
Highest number M code out of an M code number area which is reserved for channel sysn-
chronization.
The number of M codes must not exceed a number of 10 times the number of channels
(for example: 2 channels results in max. 20 M codes).
Alarm 4170 is issued if an excessive M code area is specified.
EXTERN_M_NO_SET_INT
ASUP activating M code
Minimum input limit: 0
Protection level: 2/7
M code to activate interruption type subprogram call in ISO dialect T/M mode (ASUP).
SINUMERIK 802D sl/840D sl840D/840Di sl/840Di/810D ISO Turning - - 04.07 Edition
Maximum input limit: 4
Unit: - -
Applies with effect from SW version: 5.2
Maximum input limit:
Unit: - -
Applies with effect from SW version: 6.2
Maximum input limit:
Unit: - -
Applies with effect from SW version: 6.2
Maximum input limit:
Unit: - -
Applies with effect from SW version: 6.2
© SIEMENS AG 2007 All rights reserved
04.07

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents