Machine and Setting Data

D.1 Machine/Setting Data

10652
MD number
Default setting: "ANG"
Changes effective after Power On
Datentype: STRING
Meaning:
This MD cannot SINUMERIK 802D sl.
10654
MD number
Default setting: "RND"
Changes effective after Power On
Data type: STRING
Meaning:
This MD cannot SINUMERIK 802D sl.
10656
MD number
Default setting: "CHR"
Changes effective after Power On
Data type: STRING
Meaning:
This MD cannot SINUMERIK 802D sl.
D-200
CONTOUR_DEF_ANGLE_NAME
Definable name for angle in the contour short description
Minimum input limit: - -
Protection level: 2/7
The setting is effective for Siemens G code programming only, i.e. G290.
The name used to program the angle in the contour short description is definable. This
allows, for example, identical programming in different language modes:
If the angle is named "A", it is programmed in the same way with Siemens and ISO Dia- -
lect0.
The name must be unique, i.e. axes, variables, macros, etc. must not exist with the same
name.
RADIUS_NAME
Definable name for radius non- -modally in the contour short description
Minimum input limit: - -
Protection level: 2/7
The name used to program the radius in the contour short description is definable. This
allows, for example, identical programming in different language modes:
If the radius is named "R", it is programmed in the same way with Siemens and ISO Dia- -
lect0.
The name must be unique, i.e. axes, variables, macros, etc. must not exist with the same
name.
The setting is effective for Siemens G code programming, i.e. G290.
CHAMFER_NAME
Definable name for chamfer in the contour short description
Minimum input limit: - -
Protection level: 2/7
The name used to program the chamfer in the contour short description is definable. This
allows, for example, identical programming in different language modes:
If the chamfer is named "C", it is programmed in the same way with Siemens and ISO Dia- -
lect0.
The name must be unique, i.e. axes, variables, macros, etc. must not exist with the same
name.
The setting is effective for Siemens G code programming, i.e. G290.
The chamfer in the original direction of movement. Alternatively, the chamfer length can be
programmed with the name CHF.
SINUMERIK 802D sl/840D sl840D/840Di sl/840Di/810D ISO Turning - - 04.07 Edition
Maximum input limit:
Unitt: - -
Applies with effect from SW version: 5
Maximum input limit: - -
Unit: - -
Applies with effect from SW version: 5
Maximum input limit: - -
Unit: - -
Applies with effect from SW version: 5