Machine and Setting Data
D.1 Machine/Setting Data
10818
MD number
Default setting: 2
Changes effective after
Data type: BYTE
Meaning:
10820
MD number
Default setting: 1
Changes effective after
Data type: BYTE
Meaning:
10880
MD number
Default setting: 0
Changes effective after Power On
Data type: WORD
Meaning:
10881
SD number
Default setting: 0
Changes effective after Power On
Data type: DWORD
Meaning:
D-208
EXTERN_INTERRUPT_NUM_ASUP
Interruptnumber for ASUP start (M96)
Minimum input limit: 1
Protection level:
Number of the interrupt input with which an asynchronous subprogram activated in ISO
mode is started (M96<program number>.
EXTERN_INTERRUPT_NUM_RETRAC
Interruptnumber for retract (G10.6)
Minimum input limit: 1
Protection level:
Number of the interrupt input with which, in ISO mode, fast retraction to the position pro-
grammed with G10.6 is triggered (M96 <Programmnummer>).
EXTERN_CNC_SYSTEM
External control system whose programs are executed
Minimum input limit: 0
Protection level: 2/7
Selection of the external language
1 = ISO- -2: System Fanuc0 Milling (from 5.1)
2 = ISO- -3: System Fanuc0 Turning (from 5.2)
The functional scope defined in the current Siemens documentation is valid.
This data is only evaluated if machine data $MN_MM_EXTERN_LANGUAGE is set.
EXTERN_GCODE_SYSTEM
ISO mode T: G code system
Minimum input limit: 0
Protection level: 2/7
This MD deternines the G code system used for ISO dialect T mode:
setting value = 0:
setting value = 1:
setting value = 2:
SINUMERIK 802D sl/840D sl840D/840Di sl/840Di/810D ISO Turning - - 04.07 Edition
Maximum input limit: 8
Applies with effect from SW version: 6.2
Maximum input limit:: 8
Applies with effect from SW version: 6.2
Maximum input limit: 2
Applies with effect from SW version: 5
Maximum input limit: 2
Applies with effect from SW version: 6.2
ISO_T: G code system B
ISO_T: G code system A
ISO_T: G code system C
© SIEMENS AG 2007 All rights reserved