Crankcase Breather - Install - Perkins 1106D Disassembly And Assembly

Industrial engine
Table of Contents

Advertisement

104
Disassembly and Assembly Section
Illustration 205
Illustration 206
2. Remove the canister (20) for the breather. Refer to
Operation and maintenance Manual, "Crankcase
Breather (Canister) - Replace".
3. Loosen the clamp (19) and remove the hose (21).
4. Release the two spring clamps (14) in order to
remove the hose (15). Remove the hose.
5. Remove the two setscrews (17). Remove the
base (18) from the inlet manifold (not shown).
If a spacer is installed between the base and the
inlet manifold, remove the spacer (16).
6. Carefully pry the cover (1) from the breather body
(4).
Note: Note the orientation of the outlet.
7. Remove the gauze (2) from the breather body (4).
8. Remove the O-ring seal (3) from the breather
body (4). Discard the O-ring seal.
9. Use Tooling (A) in order to unscrew the breather
body (4) from the adapter plate (8).
10. Remove the O-ring seal (5) from breather body
(4). Discard the O-ring seal.
11. Remove the two setscrews (6) and the washers
(7) from adapter plate (8).
12. Remove adapter plate (8) from the valve
g01200785
mechanism cover (10).
13. Remove the O-ring seal (9) from adapter plate
(8). Discard the O-ring seal.

Crankcase Breather - Install

Installation Procedure (Unfiltered
Breather)
Table 49
Tool
A
g01200786
Required Tools
Part
Part Description
Number
-
Breather Tool
SENR9983
i02403277
Qty
1

Advertisement

Table of Contents
loading