Engine Crankcase Breather - Replace
Illustration 30
Typical service indicator
Observe the service indicator. The air cleaner
element should be cleaned or the air cleaner element
should be replaced when one of the following
conditions occur:
The yellow diaphragm enters the red zone.
The red piston locks in the visible position.
Test the Service Indicator
Service indicators are important instruments.
Check for ease of resetting. The service indicator
should reset in less than three pushes.
Check the movement of the yellow core when the
engine is accelerated to the engine rated speed.
The yellow core should latch approximately at the
greatest vacuum that is attained.
If the service indicator does not reset easily, or if the
yellow core does not latch at the greatest vacuum,
the service indicator should be replaced. If the new
service indicator will not reset, the hole for the service
indicator may be restricted.
The service indicator may need to be replaced
frequently in environments that are severely dusty.
This document has been printed from SPI². Not for Resale
Engine Crankcase Breather -
Replace
1106 Engines
g00103777
Illustration 31
1106 Closed breather system
(1) Fastening bolt
(2) Top hose
(3) Top hose clamp
(4) Breather assembly
(5) Bottom hose clamp
(6) Bottom hose
Remove the breather assembly
1. Loosen the top hose clamp (3) and the bottom
hose clamp (5). Remove both the hoses (2) and
(6) from the breather assembly (4).
2. Remove the outlet hose (not shown) for the
breather .
3. Remove the two bolts (1) and remove the breather
assembly from the engine.