Perkins 1106D Disassembly And Assembly page 103

Industrial engine
Table of Contents

Advertisement

SENR9983
3. Carefully pry the cover (1) from the breather body
(4).
Note: Note the orientation of the outlet.
4. Remove the gauze (2) from the breather body (4).
5. Remove the O-ring seal (3) from the breather
body (4). Discard the O-ring seal.
6. Use Tooling (A) in order to unscrew the breather
body (4) from the adapter plate (8).
7. Remove the O-ring seal (5) from breather body
(4). Discard the O-ring seal.
8. Remove the two setscrews (6) and the washers
(7) from adapter plate (8).
9. Remove adapter plate (8) from the valve
mechanism cover (10).
10. Remove the O-ring seal (9) from adapter plate
(8). Discard the O-ring seal.
Removal Procedure (Filtered
Breather)
Table 48
Required Tools
Part
Tool
Number
-
A
Breather Tool
NOTICE
Keep all parts clean from contaminants.
Contaminants may cause rapid wear and shortened
component life.
Part Description
Qty
1
Disassembly and Assembly Section
Illustration 204
Breather tool
1. To remove the breather body, Tooling (A) must be
used. The tool should be fabricated from 3.1 mm
(1/8 inch) steel stock. The dimensions for the tool
are given in Illustration 204. All dimensions are
shown in millimeters.
103