Danfoss VLT HVAC Basic Drive FC 101 Programming Manual page 33

Hide thumbs Also See for VLT HVAC Basic Drive FC 101:
Table of Contents

Advertisement

Parameters
3.2.2 1-10 to 1-13 Motor Selection
NOTICE
This parameter group cannot be adjusted while the
motor is running.
The following parameters are active ('x') depending on the
setting of parameter 1-10 Motor Construction.
Parameter 1-10 Motor
Construction
Parameter 1-00 Configuration
Mode
Parameter 1-03 Torque Character-
istics
Parameter 1-06 Clockwise
Direction
Parameter 1-08 Motor Control
Bandwidth
Parameter 1-14 Damping Gain
Parameter 1-15 Low Speed Filter
Time Const.
Parameter 1-16 High Speed Filter
Time Const.
Parameter 1-17 Voltage filter time
const.
Parameter 1-20 Motor Power [kW]
Parameter 1-22 Motor Voltage
Parameter 1-23 Motor Frequency
Parameter 1-24 Motor Current
Parameter 1-25 Motor Nominal
Speed
Parameter 1-26 Motor Cont. Rated
Torque
Parameter 1-29 Automatic Motor
Adaption (AMA)
Parameter 1-30 Stator Resistance
(Rs)
Parameter 1-33 Stator Leakage
Reactance (X1)
Parameter 1-35 Main Reactance
(Xh)
Parameter 1-37 d-axis Inductance
(Ld)
Parameter 1-38 q-axis Inductance
(Lq)
Parameter 1-39 Motor Poles
Parameter 1-40 Back EMF at 1000
RPM
Parameter 1-42 Motor Cable
Length
Parameter 1-43 Motor Cable
Length Feet
MG18B502
Programming Guide
[1] PM,
[3] PM,
[0]
non-
salient
Asynchron
salient
IPM,
SPM
Sat.
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
Danfoss A/S © 04/2018 All rights reserved.
Parameter 1-10 Motor
Construction
Parameter 1-44 d-axis Inductance
Sat. (LdSat)
Parameter 1-45 q-axis Inductance
Sat. (LqSat)
Parameter 1-46 Position Detection
Gain
Parameter 1-48 Current at Min
Inductance for d-axis
Parameter 1-49 Current at Min
Inductance for q-axis
Parameter 1-50 Motor Magneti-
sation at Zero Speed
Parameter 1-52 Min Speed Normal
Magnetising [Hz]
Parameter 1-55 U/f Characteristic
- U
Parameter 1-56 U/f Characteristic
- F
Parameter 1-62 Slip Compensation
Parameter 1-63 Slip Compensation
Time Constant
Parameter 1-64 Resonance
Dampening
Parameter 1-65 Resonance
Dampening Time Constant
Parameter 1-66 Min. Current at
Low Speed
Parameter 1-70 Start Mode
Parameter 1-71 Start Delay
parameter 1-72 Start Function
Parameter 1-73 Flying Start
Parameter 1-80 Function at Stop
Parameter 1-90 Motor Thermal
Protection
parameter 2-00 DC Hold Current
Parameter 2-01 DC Brake Current
Parameter 2-02 DC Braking Time
Parameter 2-04 DC Brake Cut In
Speed [Hz]
Parameter 2-06 Parking Current
Parameter 2-07 Parking Time
Parameter 2-10 Brake Function
Parameter 2-16 AC brake Max.
Current
Parameter 2-17 Over-voltage
Control
Parameter 4-10 Motor Speed
Direction
Parameter 4-14 Motor Speed High
Limit [Hz]
Parameter 4-18 Current Limit
[1] PM,
[3] PM,
[0]
non-
salient
Asynchron
salient
IPM,
SPM
Sat.
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
31