ASX-112FR Autosampler Operator's Manual
Chapter 1: Introduction
The following components are located on the front of the autosampler and are
shipped with the autosampler. Each lettered item corresponds with a callout in
Figure 1-2.
Rotary Tray. The rotary tray has 14 standard positions and a rectangular
center cavity, which holds one sample rack in place.
A
Sample Rack Location. The ASX-112FR includes one sample rack. Rack
choices include short or tall rack configurations. A keyed interface plate is
B
required to use the short racks. The tall racks are placed directly in the rotary
tray with no interface plate required. The appropriate sample vials must be
used for each rack, and the host computer's software must be configured for
that particular rack layout and number of positions. The identification
designations are shown in the host computer's software – if the software does
not include a specific reference for the ASX-112FR, a reference for the older
model ASX-100 may be applicable with the ASX-112FR tray files.
 Short – CETAC Racks:
24 position, 1.5 mL or 2.0 mL vials
48 position, 0.5 mL vials
96 position, 1.0 mL vials
 Tall – Bel-Art Half Racks:
30 position, 14 mL vials
42 position, 7 mL vials
Standards Vials. Up to 14 standards positions are available with the
autosampler:
C
Short
9 – 4 mL vials
Dual Flowing Rinse Station. The dual rinse station is located next to the
5 – 20 mL vials
sample tray. It comes with tubing used to connect the rinse station to two
D
separate rinse sources (deionized water pre-rinse and acid full rinse) and the
waste container. The rinse station is provided in either a short or tall version
to match the rack choice.
E
Rinse Alignment Block.
Y-Arm Assembly. The Y-arm is attached to the Z-drive assembly in one of
F
Z-Drive Assembly.
three mounting locations depending upon the choice for short or tall function.
G
Sample Probe. Sample probes are constructed of fluoropolymer tubing
reinforced with a carbon fiber or polyimide tube to provide strength and
H
maintain straightness. Available probe sizes include 0.010" (0.25 mm) ID,
0.010" (0.25 mm) ID, and 0.035" (0.89 mm) ID. If the ASX-112FR is used with
the Aridus II or Aridus3, then the uptake line of the C-Flow PFA nebulizer
(equipped with a polyimide support tube) is used as the sample probe.
Power Switch. Rocker switch, single pole-single throw, 16 amp.
I
10
Tall
9 – 10 mL vials
5 – 30 mL vials