Toyota Celica 2005 Repair Manual page 327

Hide thumbs Also See for Celica 2005:
Table of Contents

Advertisement

DI−128
2
Check the output voltage of oxygen sensor during idling.
PREPARATION:
(a)
Connect the hand−held tester or the OBD II scan tool to the DLC3.
(b)
Start the engine and push the hand−held tester or the OBD II scan tool main switch ON.
(c)
When using hand−held tester, enter the following menus: DIAGNOSIS / ENHANCED OBD II / DATA
LIST / ALL / O2S B1S1.
(d)
Warm up the heated oxygen sensor with the engine speed at 2,500 rpm for approximately 90 seconds.
CHECK:
Read the output voltage of the heated oxygen sensor during idling.
OK:
Heated oxygen sensor output voltage:
Alternates between less than 0.35 V and more than 0.45 V, and period of "t" must be less than
0.6 sec. (See the following table).
1V
0.45V
0.35V
0V
NG
2005 CELICA (RM1131U)
DIAGNOSTICS
OK
NG
t
t
0.6 sec. or more
OK
ENGINE (1ZZ−FE)
NG
NG
Go to step 9.
326
NG
A21567