Error Messages - Steinberg AXR4T Operation Manual

Hide thumbs Also See for AXR4T:
Table of Contents

Advertisement

Error Messages

Error Message
Too Many Devices
Duplicated STACK ID
Sync Error
Sample Rate Mismatch
Turn off +48V or HI-Z
Insufficient DSP Resources
Audio Format is Unmixable
Display Area
Driver (Control Panel)
dspMixFx AXR
Display
Driver (Control Panel)
dspMixFx AXR
Display
Driver (Control Panel)
Driver (Control Panel)
Display
dspMixFx AXR
AXR Extension (Dedicated
Cubase Window)
dspMixFx AXR
AXR Extension (Dedicated
Cubase Window)
Driver (Control Panel)
Cause
Four or more AXR4s are
connected to the computer
Duplicate STACK IDs are
in use
Cannot synchronize the
AXR4s connected to the
computer
The driver cannot set the
same sample rate when
multiple AXR4s are
connected because each
AXR4 uses a different
clock source
You have attempted to turn
on the phantom power and
HI-Z at the same time
Insufficient DSP resources.
Cannot insert effect
Cubase was not properly
exited from when running
in 32-bit resolution.
Error Messages
Solution
Reduce the number of
connected devices to
three or less
Change the STACK ID so
that it does not repeat
Power on/standby, remove
and reinsert the
Thunderbolt cable
Set the same clock source
for all AXR4s
None
(Use one or the other)
Reduce the number of
inserted effects
Click the [Revert to
Mixable] button that
appears next to the error
message (if you cannot
record or playback audio
properly in the application
after closing Cubase)
AXR4 Operation Manual
74

Advertisement

Table of Contents
loading

Table of Contents