2 Initial Delay
Adjusts the time that elapses between the
direct, original sound and the initial
reflections that follow it.
Range: 0.1 msec – 200.0 msec
3 Decay
Adjusts the characteristic of the envelope
from the moment the reverberation starts
to the moment it attenuates and stops.
Range: 0 – 63
4 Room Size
Adjusts the size of the simulated room.
This parameter links to Reverb Time.
Range: 0 – 31
5 Diffusion
Adjusts the spread of the reverberation.
Range: 0 – 10
6 HPF
Adjusts the cutoff frequency of the high
pass filter.
Range: 20 Hz – 8.0 kHz
7 LPF
Adjusts the cutoff frequency of the low
pass filter.
Range: 1.0 kHz – 20.0 kHz
8 Hi Ratio
Adjusts the duration of reverberation in the
high frequency range by using a ratio
relative to the Reverb Time.
When you set this parameter to 1.0, the
actual specified Reverb Time is fully
applied to the sound. The lower the value,
the shorter the duration of reverberation in
the high frequency range.
Range: 0.1 – 1.0
9 Low Ratio
Adjusts the duration of reverberation in the
low frequency range by using a ratio
relative to the Reverb Time.
When you set this parameter to 1.0, the
actual specified Reverb Time is fully
applied to the sound. The lower the value,
the shorter the duration of reverberation in
the low frequency range.
Range: 0.1 – 1.4
Panel Controls and Functions (Software)
) Low Freq
Adjusts the frequency of the Low Ratio.
Range: 22.0 Hz – 18.0 kHz
! OPEN/CLOSE
Opens and closes the window for
adjusting the reverb settings.
@ Graph
Indicates the characteristics of
reverberation. The vertical axis indicates
the signal level, the horizontal axis
indicates the time, and the Z-axis indicates
the frequency. You can adjust the
characteristics of reverberation by
dragging the handles in the graph.
# Time Axis Setting
Select the display range of the time
(horizontal axis) on the graph.
Display range: 500 msec – 50 sec
$ Zoom Out
Zooms out the display range of the time
(horizontal axis) on the graph.
% Zoom In
Zooms in the display range of the time
(horizontal axis) on the graph.
Software Functions
• You can reset certain parameters to their
default values by holding the <command>
key while you click on the appropriate
knobs, sliders, and faders.
• You can adjust the parameters more finely
by holding the <shift> key while you drag on
the appropriate knobs, sliders, and faders.
AXR4 Operation Manual