Example Of The 6Th Telegram (All Values Are Hexadecimal) - ABB A43 User Manual

Hide thumbs Also See for A43:
Table of Contents

Advertisement

Communication with M-Bus
Byte No.
129
130
131
132-133
134
135
136
137
138-143
144
145
146
147
148
149
150-155
156
157
158
159
160
161
162-167
168
169
170

10.3.6 Example of the 6th telegram (all values are hexadecimal)

Byte No.
1
2
3
4
5
6
7
8-11
12-13
14
15
16
A43/A44
User Manual
Size
Value
1
FF
1
A4
1
xx
4
xxxxxxxx
1
04
1
FF
1
A5
1
xx
4
xxxxxxxx
1
8E
1
80
1
80
1
40
1
84
1
xx
6
xxxxxxxxxxxx
1
8E
1
C0
1
80
1
40
1
84
1
xx
6
xxxxxxxxxxxx
1
1F
1
xx
1
16
Size
Value
1
68
1
F7
1
F7
1
68
1
08
1
xx
1
72
4
xxxxxxxx
2
4204
1
02
1
02
1
xx
216
Description
VIFE next byte is manufacturer specific
CO2 conversion factor in g/kWh
VIFE status
CO2 conversion factor for active energy
DIF size, 32 bit integer
VIFE next byte is manufacturer specific
Currency conversion factor in 0,001 currency/kWh
VIFE status
Currency conversion factor for active energy
DIF size, 12 digit BCD
DIFE
DIFE
DIFE, Unit 4
VIF for unit kVAh with resolution 0,01kVAh
VIFE status
Apparent imported energy, Total
DIF size, 12 digit BCD
DIFE, Unit bit 0
DIFE, Unit bit 1
DIFE, Unit bit 2, Unit bit 0-2 -> Unit 5
VIF for unit kVAh with resolution 0,01kVAh
VIFE status
Apparent exported energy, Total
DIF, more records will follow in next telegram
CS checksum, calculated from C field to last data
Stop character
Description
Start character
L-field, calculated from C field to last user data
L-field, repeated
Start character
C-field, RSP_UD
A-field, address
CI-field, variable data respond, LSB first
Identification Number, 8 BCD digits
Manufacturer: ABB
Version
Medium, 02 = Electricity
Number of accesses
2CMC48001M0201
Revision: C

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

A44

Table of Contents