A B B M E A S U R E M E N T & A N A LY T I C S | U S E R G U I D E S U P P L E M E N T | I M/A X 4/ P B S R E V. D
AX400 series
Single and dual input analyzers
For more information
AX400 series
analyzers
Further publications are available for free download
from:
www.abb.com/analytical
or by scanning this code:
Data Sheet
AX410, AX411, AX416, AX450 and AX455
Single and dual input analyzers for low level conductivity
Data Sheet
AX430, AX433, AX413 and AX436
Single and dual input analyzers for high level conductivity
User Guide
AX410, AX411, AX413, AX416, AX418, AX450, AX455 and AX456
Single and dual input analyzers for low level conductivity
User Guide
AX413, AX430, AX433, AX436 and AX438
Single and dual input analyzers for high level conductivity
PROFIBUS® datalink description
Measurement made easy
Search for or click on
DS/AX4CO-EN
Data Sheet
AX460, AX466 and AX416
Single and dual input analyzers for pH/Redox (ORP)
DS/AX4CO4-EN
User Guide
AX416, AX436, AX460, AX466 and AX468
Single and dual input analyzers for pH/Redox (ORP)
IM/AX4CO
Data Sheet
AX480, AX488 and AX468
Single and dual input analyzers for dissolved oxygen
IM/AX4CO4
User Guide
AX418, AX438, AX480, AX468 and AX488
Single and dual input analyzers for dissolved oxygen
User Guide Supplement | PID control
AX460
Single input pH/Redox (ORP) analyzer
Search for or click on
DS/AX4PH-EN
IM/AX4PH
DS/AX4DO-EN
IM/AX4DO
IM/AX4PID

Advertisement

Table of Contents
loading

Summary of Contents for ABB AX400 Series

  • Page 1 A B B M E A S U R E M E N T & A N A LY T I C S | U S E R G U I D E S U P P L E M E N T | I M/A X 4/ P B S R E V. D AX400 series Single and dual input analyzers PROFIBUS®...
  • Page 2 Electrical safety Health and safety This equipment complies with the requirements of CEI/IEC To ensure that our products are safe and without risk to health, 61010-1:2001-2 ‘Safety Requirements for Electrical Equipment the following points must be noted: for Measurement, Control and Laboratory Use’. If the •...
  • Page 3: Table Of Contents

    The central controller or 'master' device (e.g. PLC or PC) utilizes PROFIBUS-DP as a fast serial connection with distributed (slave) field devices such as PROFIBUS-enabled AX400 Series analyzers. The master reads the input information cyclically in a defined, recurring order from the slave(s).
  • Page 4: Profibus And Abb Products

    ABB's Industrial IT provides all the The bus structure enables addition and removal of stations or technology to realize the benefits of fieldbus-enabled devices,...
  • Page 5: Installation

    Suitable PROFIBUS cable, Part Nos. PCA010, PCA 011 and supply. PCA 012, can be obtained from ABB. Refer to Data Sheet Up to three line bus amplifiers (repeaters) can be used to extend 10/63-6.46 EN.
  • Page 6: Network Connection And Configuration

    3 NETWORK CONNECTION AND CONFIGURATION Warnings. When connecting a PROFIBUS-enabled AX400 Series analyzer to a PROFIBUS-DP network: • Use shielded data lines and ensure they are not reversed. • Ensure all data lines are routed clear of the source of any strong electrical and magnetic fields.
  • Page 7: Network Configuration

    3 NETWORK CONNECTION AND CONFIGURATION 3.2 Network Configuration Note. An AX400 Series analyzer is not configured using PROFIBUS commands but via the analyzer's keypad and menu system. Configure the analyzer for PROFIBUS communication as shown below. Configure Serial Communications Refer to relevant User Guide and access the page.
  • Page 8: Appendix A - Gsd File Modules

    APPENDIX A – GSD FILE MODULES A1.3 Module 03 Note. Module 03 contains the following AX400 analyzers that output • Float = Floating-point number – requires 4 bytes 24 bytes of data: • Char = Character – requires 1 byte •...
  • Page 9: A1.5 Sensor Status Message

    A1.6 Alarm Status Table A.6 shows the alarm that is associated with each bit of the alarm status byte for each AX400 Series analyzer variant. Note. Alarms 4 and 5 are available only if the option board is fitted to the instrument and analog features enabled –...
  • Page 10 NOTES...
  • Page 11 Acknowledgments PROFIBUS is a registered trademark of PROFIBUS and PROFINET International (PI). Sales Service...
  • Page 12 We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document.