ABB A43 User Manual page 234

Hide thumbs Also See for A43:
Table of Contents

Advertisement

Communication with M-Bus
Read request for load profile with channel number specified
A read request for a load profile with channel no. specified as input is
performed by sending the following SND_UD to the meter followed by a
REQ_UD2 (all values are hexadecimal). Sending no date or date/time will
result in that the meter start by sending out the most recent data.
Byte No.
Size
1
1
2
1
3
1
4
1
5
1
6
1
7
1
8
1
9
1
10
1
11
1
12
1
13
1
14
1
15
1
16
1
The data is sent out with a number of profile values in each telegram.
Comments
The first data item sent out in each telegram is the interval length.
After that the date/time for the end of the interval followed by the data value for
that interval is sent out
All load profile energy values and input counters are read as register values, that
is snapshots of the register at the end of the interval. All other load profile
values, for example voltages, currents, power factors, THD's are read as interval
average values.
All load profile values have storage number 1 to indicate that it is stored
historical data.
A43/A44
User Manual
Value
Description
68
Start character
0A
L-field, calculated from C field to last user data
0A
L-field, repeated
68
Start character
53/73
C-field, SND_UD
xx
A-field, address
51
CI-field, data send, LSB first
00
DIF size, no data
FF
VIF next byte is manufacturer specific
F9
VIFE extension of manufacturer specific VIFE's, next VIFE
specifies actual meaning.
B8
VIFE specifying reading based upon the channel number
FF
VIFE next byte is manufacturer specific
F8
VIFE next byte is manufacturer specific, used for numbering
xx
VIFE specifies channel number (1-8)
xx
CS checksum, calculated from C field to last data
16
Stop character
234