ABB A43 User Manual page 231

Hide thumbs Also See for A43:
Table of Contents

Advertisement

Communication with M-Bus
Read request for a specified date and channel number
A read request for a specified date and channel number is performed by sending
the following SND_UD to the meter followed by a REQ_UD2 (all values are hexa‐
decimal).
Byte No.
Size
1
1
2
1
3
1
4
1
5
1
6
1
7
1
8
1
9
1
10
1
11
1
12
1
13
1
14
1
15-16
2
17
1
18
1
Read request for a specified date, time and quantity
A read request for a specified date, time and quantity is performed by sending
the following SND_UD to the meter followed by a REQ_UD2 (all values are
hexa-decimal).
Byte No.
Size
1
1
2
1
3
1
4
1
5
1
6
1
7
1
8
1
9
1
10
1
2CMC48001M0201
Revision: C
Value
Description
68
Start character
0D
L-field, calculated from C field to last user data
0D
L-field, repeated
68
Start character
53/73
C-field, SND_UD
xx
A-field, address
51
CI-field, data send, LSB first
02
DIF size, 2 byte integer
EC
VIF time point, date, M-Bus data type G
FF
VIFE next byte is manufacturer specific
F9
VIFE extension of manufacturer specific VIFE's, next VIFE
specifies actual meaning.
B8
VIFE specifying readout based on channel number
FF
VIFE next byte is manufacturer specific
xx
VIFE specifying data channel number
xxxx
Date (M-Bus data type G, LSB byte sent first)
xx
CS checksum, calculated from C field to last data
16
Stop character
Value
Description
68
Start character
0E
L-field, calculated from C field to last user data
0E
L-field, repeated
68
Start character
53/73
C-field, SND_UD
xx
A-field, address
51
CI-field, data send, LSB first
0E
DIF size, 12 digit BCD data
ED
VIF time point, date, M-Bus data type G
FF
VIFE next byte is manufacturer specific
231
A43/A44