Communication with Modbus
Structure of
The following table describes the structure of the data blocks:
the data blocks
Channel
Common for
all channels
Channel 1
Channel 1
Channel 1
Channel 1
Channel 1
...
...
Channel 8
Channel 8
Channel 8
Channel 8
Channel 8
Status register
The status register shows the status for a value stored at a given timestamp.
Possible values are shown in the table below:
Status
0
1
2
A43/A44
User Manual
Contents
Start
Size
Reg
(Hex)
Timestamp
8010
3
Quantity
8013
3
Data type
8016
1
Scaler
8017
1
Status
8018
1
Value
8019
4
Quantity
8059
3
Data type
805C
1
Scaler
805D
1
Status
805E
1
Value
805F
4
Description
OK
Not available
Data error
128
Description
Date and time for the end if this period,
i.e. when this entry was stored. (Date/
Time format)
OBIS code for the quantity stored in
channel 1.
Data type for quantity stored in channel
1.
Scaler for quantity stored in channel 1.
Status for quantity stored in channel 1.
Value for quantity stored in channel 1.
OBIS code for the quantity stored in
channel 8.
Data type for quantity stored in channel
8.
Scaler for quantity stored in channel 8.
Status for quantity stored in channel 8
Value for quantity stored in channel 8.