10.4.4 Readout of Event Log Data

Read request
Each one of the existing logs can be read by sending the following SND_UD to the meter
followed by a REQ_UD2 (all values are hexadecimal).
Byte No. Size Value
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17-22
23
24
2CMC48001M0201
Revision: C
Description
1
68
Start character
1
12
L-field, calculated from C field to last user data
1
12
L-field, repeated
1
68
Start character
1
53/73
C-field, SND_UD
1
xx
A-field, address
1
51
CI-field, data send, LSB first
1
8E or EC
DIF size, 6 byte BCD, storage number bit 0 is 0 or 1
1
8x or Cx
DIFE storage number bits 1-4, unit bit 6 is 0 or 1
1
8x
DIFE storage number bits 5-8
1
8x
DIFE storage number bits 9-12
1
0x
DIFE storage number bits 13-16
2
ED
VIF time/date
1
FF
VIF next byte is manufacturer specific
1
F9
VIF extension of manufacturer specific VIFE's, next
VIFE specifies actual meaning.
1
1A
VIFE Specification for different Logs:
System Log = 0x2e
Net Quality Log = 0x30
Event Log = 0x32
6
xxxxxxxxxxxx Time/date (sec:min:hour / day-month-year)
1
xx
CS checksum, calculated from C field to last data
1
16
Stop character