Communication with M-Bus
Byte No.
67
68
69
70
71
72
73-78
79
80
81
A43/A44
User Manual
Size
Value
1
80
1
80
1
40
1
FD
1
61
1
xx
6
xxxxxxxxxxxx
1
0F
1
xx
1
16
228
Description
DIFE, storage number bit 1-4, unit bit 0
DIFE, unit bit 1
DIFE, unit bit 2
VIF FD -> next VIFE specifies type of value
Cumulation counter
VIFE status
Number of pulses registered on input 4
DIF indicating that this is the last telegram
CS checksum, calculated from C field to last data
Stop character