3 Error Tables
Event code
Event name
5401546E hex
Duplicate Latch ID
for Trigger Input
Condition
5401546F hex
Jerk Override Fac-
tor Out of Range
54015470 hex
Accelera-
tion/Deceleration
Override Factor
Out of Range
54015471 hex
First Position
Method Specifica-
tion Out of Range
54015472 hex
Motion Control
Instruction Re-exe-
cution Disabled
(First Position
Method)
54015474 hex
Unused Axis Spec-
ification for Auxil-
iary Axis
54015475 hex
Position Gear
Value Error
54015476 hex
Position Gear Mas-
ter Axis Zero
Velocity
3-36
Meaning
The same latch ID was
• The same latch ID is
specified for more than one
motion control instruction.
• The MC_AbortTrigger
The parameter specified for
• Instruction input
the JerkFactor input vari-
able to a motion control
instruction is out of range.
The parameter specified for
• Instruction input
the AccFactor input vari-
able to a motion control
instruction is out of range.
The parameter specified for
• Instruction input
the StartMode input vari-
able to a motion control
instruction is out of range.
An attempt was made to
• A parameter for an
change the StartMode
input variable when re-exe-
cuting a motion control
instruction. (This input vari-
able cannot be changed
when re-executing an
instruction.)
• The axis specified for
The axis specified for the
Auxiliary input variable to a
motion control instruction is
an unused axis.
Synchronized motion is not
• The specified synchro-
possible for the velocity,
acceleration rate, and
deceleration rate that were
input to a motion control
instruction.
The velocity of the master
• The velocity of the
axis was zero when a
motion control instruction
was started.
Assumed cause
Maj
Prt
used simultaneously
for more than one of
the following instruc-
tions:
MC_TouchProbe
(Enable External
Latch) instruction,
MC_MoveLink (Syn-
chronous Positioning)
instruction, and
MC_MoveFeed (Inter-
rupt Feeding) instruc-
tion.
(Disable External
Latch) instruction was
executed to cancel a
latch that was used by
an instruction other
than the
MC_TouchProbe
(Enable External
Latch) instruction.
parameter exceeded
the valid range of the
input variable.
parameter exceeded
the valid range of the
input variable.
parameter exceeded
the valid range of the
input variable.
input variable that can-
not be changed for re-
execution was
changed.
the Auxiliary input
variable to the instruc-
tion is an unused axis.
nized motion cannot
be performed at the
velocity, acceleration
rate, or deceleration
rate that is input to the
instruction.
master axis was 0
when the instruction
was started.
NJ-series Troubleshooting Manual (W503)
Level
Refer-
ence
Min
Obs
Info
S
NJ-series
Instruc-
tions Ref-
erence
Manual
(Cat. No.
W502)
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.

Advertisement

Table of Contents
loading

Table of Contents